Preventive Verification Test
- Identify the charge valve on the low pressure side of the refrigeration or air conditioning system and unscrew the cap.
- Connect a charging station and make the vacuum of the A/C system for at least 8 minutes.
- Check the value obtained with a pressure gauge.
- Switch off the charging station and check that the value obtained is maintained for at least 5 minutes.
- If it isn’t possible to respect this parameter it means that the leak is too big to be repaired.
Instructions for use
- Make the vacuum of the A/C system
- Connect the leak stop to the charge valve on the low pressure side of the A/C system and introduce the sealant
PLEASE NOTE: if you use an exible adapter let the air inside the hose out, before connecting it to the system - Disconnect from the A/C system
- Recharge the system following the manufacturer’s instructions
- Let the system work for at least 30 minutes to allow the leak stop to work